Air Conditioning detail syllabus for Mechanical Engineering (Repair & Maintenance), effective from 2019-2020, is collected from BTEUP 2017 Syllabus official website and presented for diploma students. PDF download is possible from official site but you can download the istudy mobile app for syllabus on mobile. The course details such as exam duration, Teaching Hr/week, Practical Hr/week, Total Marks, internal marks, theory marks, duration and credits do visit complete sem subjects post given below.

For all other bteup syllabus 5th sem repair & maintenance 2019-2020 you can visit BTEUP Syllabus 5th Sem Repair & Maintenance 2019-2020 Subjects. For all other elective subjects do refer to Electives. The detail syllabus for air conditioning is as follows.

Rationale:

Refrigeration and Airconditioning is one of the needs ofmodern society and industry. It is already recognised so asit is futile here to say anything about its importance orutility. For mechanical engineers this knowledge is an extragem. Thispaper covers Air Conditioning.

Learning Outcomes:

After undergoing this course, the students will be able to:

  • Explain Psychometric and its importance.
  • Explain the working of air conditioning system.
  • Carry out load calculation.
  • Explain the air condition equipment.
  • Carry out testing of air conditioning unit.

1. COMFORT AIRCONDITIONING (08 Periods)

For complete syllabus and results, class timetable and more pls download iStudy Mobile App. Its a light weight, easy to use, no images, no pdfs platform to make students life easier.

2. AIRCONDITIONING LOAD CALCULATIONS (16 Periods)

COLLING LOAD CALCULATIONS

Design conditions for cooling space, sensible heat gains inthe space:

  1. Heat transmission load through buildingstructure in through wall door and windows, Roof and Floor,
  2. Solar radiation heat lock
  3. Infiltration heat load
  4. Occupants heat load
  5. Electric appliances heat load
  6. Product cooling load above freezing and below freezing
  7. Outside ventilation air load
  8. Other internal heat sources.

Latent heat gain in the space:

    1. Infiltration heat load
    2. Occupants heat load
    3. Product freezing load
    4. Respiration load
    5. Miscellaneous items for latent heat load.

HEATING LOAD CALCULATIONS

Sensible heat loss:

    1. Heat Transmission loss throughbuilding structure
    2. Infiltration heat loss
    3. Productheat loss
    4. Other materials heat loss.

Latent Heat loss:

    1. Infiltration heat loss
    2. Miscellaneous items forlatent heat loss. Auxiliary heat source, Net heating capacity, intermittentlyheat building.

3. AIR CONDITIONING SYSTEM (10 Periods)

  1. Unit air-conditioning system (Window air conditioning system),Remote and split air conditioners.
  2. Package air conditioning system
    1. Package A.C. with water cooled condenser
    2. Package A.C. with air cooled condenser
  3. Central Air conditioning system
    1. D.X system with air handling unit
    2. Chilled and hot water system with fan coil unit.

4. AIR CONDITIONING EQUIPMENTS (12 Periods)

For complete syllabus and results, class timetable and more pls download iStudy Mobile App. Its a light weight, easy to use, no images, no pdfs platform to make students life easier.

5. EVAPORATOR COOLING (10 Periods)

Evaporator cooling – Thermodynamics of evaporative cooling, Types of evaporative coolers – Spray type, Pad type,Rotating type, Efficiency of evaporative cooling, Limitationof evaporative cooling, Indirector, Modified evaporativecooling system.

List of Experiments:

  1. Study and use of different refrigeration tools and equipment’s.
  2. Study of open type reciprocating compressor used in a refrigeration system.
  3. To determine the capacity for window type air conditioner.
  4. Proper method of setting and adjusting
    1. Thermostate
    2. low pressure and high pressure cutout
    3. thermostateexpersion ball
  5. Wiring of refrigerator, water cooler, desert cooler, room air conditioner, packed air conditioner, pannel board.
  6. Study of a reciprocating Hermatically Sealed Compressor.
  7. Study of electric controls such as – Over Lead Protector, Starting Relay, Potential Relay, thermostat, Solenoil Valve, Humidistat, High Pressure Control and Low Pressure Control.
  8. Study of Refrigerator (Vapour compression and Vapour absorption type).
  9. Study of water cooler and calculation of water cooling rate.
  10. Study of different refrigerant flow controls.
  11. To find out bypass factor of cooling coil, heating coil.
  12. Study of desert cooler and find out its humidifying or cooling efficiency.
  13. Study of air conditioning trainer and find out its C.O.P.

Instructional Strategy:

For complete syllabus and results, class timetable and more pls download iStudy Mobile App. Its a light weight, easy to use, no images, no pdfs platform to make students life easier.

Means of Assessment:

  1. Assignments and quiz/class tests
  2. Mid- Semester Examination
  3. Group discussion
  4. Semester Examination
  5. Presentation

Text Books:

  1. Refrigeration & Air Condition by S. C. Arora; TATA Mc Graw Hill, Delhi.
  2. Refrigeration & Air Condition by P. L. Balloney; Khanna Publishers.
  3. A Textbook of Refrigeration & Air Conditioning by R. S. Khurmi and J. K. Gupta; S. Chand.
  4. Air Conditioning Engineering by W. P. Jones; A Butterworth-heinemann Title.
  5. E-books/e-tools/relevant software to be used as recommended by AICTE/UBTE/NITTTR, Chandigarh.

For detail syllabus of all other subjects of BE Repair & Maintenance, 2019-2020 scheme do visit Repair & Maintenance 5 syllabus for 2019-2020 Scheme.

Dont forget to download iStudy Mobile App for latest syllabus and results, class timetable and more.

Leave a Reply

Your email address will not be published. Required fields are marked *

*