Power and Energy Systems Lab-II Detailed Syllabus for Power & Energy Systems M.Tech first year second sem is covered here. This gives the details about credits, number of hours and other details along with reference books for the course.
The detailed syllabus for Power and Energy Systems Lab-II M.Tech 2017-2018 (R17) first year second sem is as follows.
M.Tech. I Year II Sem.
Prerequisites: Power System Analysis, Power System Protection
Course Objectives:
- To understand the Performance of Transformers and Synchronous Machines
- To select the Transmission Lines, UG Cables, String Insulators, CTs and PTs.
- To analyze the characteristics of OC, UV/OV, negative sequence relays.
Course Outcomes: Upon the completion of the lab, the student will be able to
- Test and evaluate the performance of Power Transformers and Synchronous Machines.
- Test and evaluate the performance of Transmission lines, UG Cables, Insulators and other Auxiliary Power Systems Equipment
- Test, Evaluate/Choose the various types of Relays (Electromagnetic, Static and Microprocessor based relays)
- Determination of Equivalent circuit of a 3-Winding Transformer.
- Determination of Sequence Impedances of a Cylindrical Rotor Synchronous Machine.
- Fault Analysis:
- Single Line to Ground fault (L-G).
- Line to Line fault (L-L).
- Double Line to Ground fault (L-L-G).
- Triple Line to Ground fault (L-L-L-G).
- Determination of Sub-transient reactance’s of a Salient Pole Synchronous Machine.
- Determination of Sequence Impedances of Three Phase Transformer
- Characteristics of Over Current Relays
- IDMT Electromagnetic Relay (7051 A).
- Microprocessor based Relay (7051 B)
- Characteristics of Percentage biased Differential Relay.
- Electromagnetic Relay (7054 A).
- Static Relay (7054 B).
- Characteristics of Over Voltage Relay.
- Electromagnetic Relay (7053 A).
- Microprocessor based Relay (7053 B).
- Characteristics of Under Voltage (UV) and Negative sequence Relays
- Uv Electromagnetic Relay (7052 A).
- Uv Microprocessor Based Relay (7052 B).
- Static Negative Sequence Relay (7055 B).
- Performance and Testing of Generator Protection System.
- Performance and Testing of Transformer Protection System.
- Performance and Testing of Feeder Protection System.
- Performance and Testing of Transmission Line Model.
- Differential protection on Single Phase Transformer.
Note: From the above list minimum 10 experiments are to be conducted
For all other M.Tech 1st Year 2nd Sem syllabus go to JNTUH M.Tech Power & Energy Systems 1st Year 2nd Sem Course Structure for (R17) Batch.
All details and yearly new syllabus will be updated here time to time. Subscribe, like us on facebook and follow us on google plus for all updates.
Do share with friends and in case of questions please feel free drop a comment.