JNTUH M.Tech 2017-2018 (R17) Detailed Syllabus Medical Instrumentation

Medical Instrumentation Detailed Syllabus for Biomedical Signal Processing and Instrumentation M.Tech first year first sem is covered here. This gives the details about credits, number of hours and other details along with reference books for the course.

The detailed syllabus for Medical Instrumentation M.Tech 2017-2018 (R17) first year first sem is as follows.

M.Tech. I Year I Sem.

UNIT -I : Bioelectric Signals and Electrodes: Sources of biomedical signals, basic medical instrumentation system, PC based medical instruments, General constraints in design of medical instrumentation systems, origin of bioelectric signals, Electrocardiogram (ECG), Electroencephalogram (EEG), Electromyogram (EMG), Electrooculogram (EOG), Electroretinogram (ERG), Recording Electrodes – Electrode-tissue interface, polarization, skin contact impedance, motion artifacts, Silver-Silver Chloride electrodes, Electrodes for ECG, Electrodes for EEG, Electrodes of EMG, Electrical conductivity of electrode jellies and creams, microelectrodes.

UNIT -II : Biomedical Recording Systems & Recorders: Electrocardiograph-block diagram, ECG leads, effects of artifacts, multi-channel, ECG machine, Vectorcardiograph, Phonocardiograph-origin of heart sounds, microphones and amplifiers for PCG, Electroencephalograph- block diagram, computerized analysis of EEG, Electromyograph, biofeedback instrumentation.

UNIT -III : Oximeters, Blood Flow & Cardiac Output Measurement: Oximetry- In-vitro & in-vivo, ear oximetry, pulse oximetry, skin reflectance oximeters, intravascular oximeter. Electromagnetic blood flow meter principle, square wave electromagnetic flowmeter, Doppler shift ultrasonic flowmeter, flow measurement by Doppler imaging, NMR & Laser Doppler flowmeter, Cardiac output measurement Indicator & dye dilution technique, impedance method, ultrasound method.

UNIT -IV : Pacemakers & Defibrillator: Need for cardiac pacemaker, external pacemaker, implantable pacemakers-types, ventricular synchronous demand pacemaker, programmable pacemaker, power sources for implantable pacemakers. Need for defibrillator, DC defibrillator, automatic external defibrillator, implantable defibrillators

UNIT -V : Advanced Diagnostic & Therapeutic Instruments: Principle of surgical diathermy & surgical diathermy machine, Electrodiagnosis-Electrotherapy-functional block diagram and working, interferential current therapy. Artificial kidney-Principle and haemodialysis machine. Anesthesia-Need for anesthesia, delivery of anesthesia, anesthesia machine.

TEXT BOOKS:

  • R.S. Khandpur, “ Handbook of Biomedical Instrumentation”, 2nd Edition, Tata McGraw Hill, 2003
  • John G. Webster, “Medical Instrumentation Application and Design”, Willey, 4th edition.

REFERENCE BOOKS:

  • Joseph J. Carr and John M. Brown, “Introduction to Biomedical Equipment Technology” 4th Edition, Prentice Hall, 2001.
  • L. A. Geddes, L. E.Baker, “Principles of Applied Biomedical Instrumentation”, 3rd Edition. Willey, 2008
  • Tatsuo Togawa, Toshiyo Tamura and P. Ake Oberg, “Biomedical Transducers and Instruments” 1st Edition, CRC Press, 1997.

For all other M.Tech 1st Year 1st Sem syllabus go to JNTUH M.Tech Biomedical Signal Processing and Instrumentation 1st Year 1st Sem Course Structure for (R17) Batch.

All details and yearly new syllabus will be updated here time to time. Subscribe, like us on facebook and follow us on google plus for all updates.

Do share with friends and in case of questions please feel free drop a comment.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

This site uses Akismet to reduce spam. Learn how your comment data is processed.