Op Amps & Linear Circuits Lab detail DTE Kar Diploma syllabus for Electronics Instrumentation And Control Engineering (EI), C15 scheme is extracted from DTE Karnataka official website and presented for diploma students. The course code (15EI37P), and for exam duration, Teaching Hr/week, Practical Hr/week, Total Marks, internal marks, theory marks, duration and credits do visit complete sem subjects post given below. The syllabus PDFs can be downloaded from official website.
For all other instrumentation 3rd sem syllabus for diploma c15 scheme dte karnataka you can visit Instrumentation 3rd Sem Syllabus for Diploma C15 Scheme DTE Karnataka Subjects. The detail syllabus for op amps & linear circuits lab is as follows.
Pre-requisites:
Semiconductor devices and Analog Electronics.
Course Objectives:
- To impart students with the knowledge of Linear circuits.
- To conduct experiment on OP amplifiers and study their frequency response.
- To enable the students to work on various applications of OP AMP
- To conduct experiment on Instrumentation amplifiers
- Know the importance of IC 555 timer
Course Outcomes:
For complete syllabus and results, class timetable and more pls download iStudy Syllabus App. Its a light weight, easy to use, no images, no pdfs platform to make students life easier.
COURSE CONTENTS:
- Conduct an experiment using OP AMP as a Inverting amplifier 3 Hours
- Conduct an experiment using OP AMP as a Non inverting amplifier 3 Hours
- Conduct an experiment using OP AMP as a Summing amplifier 3 Hours
- Conduct an experiment using OP AMP as a Difference amplifier 6 Hours
- Conduct an experiment using OP AMP as a Integrator 3 Hours
- Conduct an experiment using OP AMP as a Differentiator 3 Hours
- Conduct an experiment using OP AMP as a Zero Crossing detector 3 Hours
- Conduct an experiment using OP AMP as a Comparator 6 Hours
- Conduct an experiment using OP AMP as Schmitt trigger 6 Hours
- Conduct an experiment using OP AMP as a Current to Voltage converter 6 Hours
- Conduct an experiment using OP AMP as a Voltage to Current Converter 6 Hours
- Conduct an experiment using OP AMP as RC Phase shift oscillator 6 Hours
- Conduct an experiment using OP AMP as a Low pass filter 6 Hours
- Conduct an experiment using OP AMP as a High pass filter 6 Hours
- Construct and test 555 Timer as Astable multivibrator 6 Hours
- Construct and test 555 Timer as Monostable multivibrator 6 Hours
Reference Books:
- Analog Electronics: L K Maheshwari & M M S Anand
- Op Amps and Linear Integrated Circuits: Ramakanth A Gayakwad
- Op Amp and Linear IC’s: David Bell
FOLLOWING WEBSITES CAN BE REFERRED FOR OP AMP LAB FOR ALL EXPERIMENTS
For complete syllabus and results, class timetable and more pls download iStudy Syllabus App. Its a light weight, easy to use, no images, no pdfs platform to make students life easier.
Few Suggested Student activities-
Example 1
- Do Market survey on List of Linear OP amps available in the market and collect the following information like IC number, characteristics, Price etc. The student should submit a handwritten report. Documents have to be maintained as a record.
- Take Quiz tests / assignments in Operational amplifiers experiments. Documents have to be maintained as a record.
- Do a power point presentation on current topics in Operational Amplifiers experiments. Documents have to be maintained as a record.
- Visit YouTube or any other sites on current topics in Operational amplifiers experiments. Listen to the lectures and submit a handwritten report and a soft copy (CD/DVD)
Example 2
A mini project based on the topics in the lab can be designed and demonstrated for relevant applications. Few examples are Listed below
- Construct and test OP AMP as Instrumentation amplifier
- Construct a band pass filter and show its frequency response
- Construct a circuit using OP AMP to add 5Volt and 2 Volt
- Convert a Sine wave to Square wave using OP AMP
Note:- The student shall do any one topic from Example 1 and any one topic from Example 2 mentioned above for the purpose of assessment. The questions set for assessment should be out come based keeping in mind the analytical and creative skills
The activity should be graded as Exemplary:- 5 Marks , Good:-4 Marks, Satisfactory:-3 Marks Developing:- 2 Marks, Unsatisfactory:- 1 Mark
Course Delivery:
The course will be delivered through lectures and presentations
SCHEME OF VALUATION
For complete syllabus and results, class timetable and more pls download iStudy Syllabus App. Its a light weight, easy to use, no images, no pdfs platform to make students life easier.
EQUIPMENT LIST FOR OP AMPS & LINEAR CIRCUITS LAB (20 PER BATCH)
- 0-30V at 2/1A continuously variable power supply with current limit 06
- Cathode Ray oscilloscope( Dual trace. 06
- Digital multimeters 06
- Analog multimeters 06
- Volt meters DC 0-15/30V 12
- Ammeters DC 0 -100mA 18
- Decade resistance boxes 18
- Decade capacitance boxes 18
- Decade Inductance meter 18
- LCR meter 06
- Signal Generator / Function generator 06
- Analog IC tester 01
- Linear IC trainer kits /Bread board 06
For detail syllabus of all other subjects of BE Instrumentation, C15 scheme do visit Instrumentation 3rd Sem syllabus for C15 scheme.
Dont forget to download iStudy Syllabus App for latest syllabus and results, class timetable and more.